3 Amp Thermal Circuit Breaker
NTE Part Number: R58-3A
Current Rating: 3 Amp (3000mA)
Typical Resistance: 0.18 Ohms
Features:
- .250" (6.35mm) Quick Connect Terminals
- Cannot be Manually Tripped
- Visual Trip Indicator
- Push Button to Reset Breaker
| ELECTRICAL CHARACTERISTICS: |
| Calibration: | Will continuously carry100% of rating.
May trip between 101% and 144%, but must trip at 145% of rating at +25°C |
| Maximum Operating Voltages: | 50 VDC; 250 VAC, @50/60HZ |
| Dielectric Strength: | 1500VAC RMS |
| Resettable Overload Capacity: | 10 times rated current |
| Interrupt Capacity: | 2000 Amps at 50 VDC 1000 Amps at 250 VAC |
| MECHANICAL CHARACTERISTICS: |
| Termination: | .250" (6.35mm) Quick Connect Terminals
NOTE: Soldering to terminals is not recommended |
| Shock: | Withstands to 10g |
| Endurance Cycling: | Over 1000 Cycles at 200% of rated load. |
| Vibration: | Withstands to 10g at 10 to 55Hz |
| Weight: | Less than 1.5ozs (42.5g) |
| TRIP TIMES: |
| 1 - 4 Amps: |
| Rated Load: | Trip Times |
| 100% | No Trip |
| 145% | Trip in 1 Hour |
| 200% | 10 to 45 Sec. |
| 400% | 3.0 to 14.0 Sec. |
| 600% | 1.4 to 7.0 Sec. |
| 800% | 0.75 to 4.3 Sec. |
| 1000% | 0.50 to 3.4 Sec. |
| Click image to enlarge Dimensions:
 |
For full specs, please see the DATASHEET.
|